The ST-DGE series conform to the EN-45545-2 (R22/R23) fire protection standards of railway vehicles.
Parameter Product name | ST-DGE |
---|---|
Features |
Flame retardant and low smoke |
Density |
1.34 |
Hardness Durometer A |
75 |
Tensile strength MPa |
6.2 |
Elongation at break % |
230 |
Tear strength kN/m |
13 |
Dielectric breakdown strength kV/mm |
27 |
Volume resistivity T·Ωm |
92 |
Flame-resistant Sheet UL-94 t=1mm |
V-0 equivalent |
Temperature range °C |
-40 to +200 |
Shrinkage in direction of diameter % |
Approx.50 |
Shrinkage temperature °C |
80 < |
Requirement | Parameter | Test method | HL3 required value | Thickness | |
---|---|---|---|---|---|
2 mm | 3 mm | ||||
R22 |
Fuming characteristic (Optical density) |
Ds max-dimensionless Smoke density (Max in 10 min) |
≤ 150 | 66 | 76 |
Smoke toxicity | CIT-dimensionless Toxicity (8 gases) |
≤ 0.75 | 0.08 | 0.07 | |
Oxygen index | Limited oxygen index (LOI) %O2 |
≥ 32 | 39.0 | 44.0 | |
R23 |
Fuming characteristic (Optical density) |
Ds max-dimensionless Smoke density (Max in 10 min) |
≤ 300 | 66 | 76 |
Smoke toxicity | CIT-dimensionless Toxicity (8 gases) |
≤ 1.5 | 0.08 | 0.07 | |
Oxygen index | Limited oxygen index (LOI) %O2 |
≥ 32 | 39.0 | 44.0 |